Welcome to unionaircompressor.com
Complete Air Compressor Solutions Starts HereUnion Air Compressor丨Screw, Piston & Industrial Air Compressors Worldwide
WhatsApp:8618267307420

3kW-250kW AC Oil-Free Diaphragm Compressor For Oxygen

Products Details

3kW-250kW AC Air-Cooled Oil-Free Stationary Diaphragm Compressor For Oxygen Cylinder Filling

A stationary AC-driven, air-cooled, oil-free metal diaphragm oxygen compressor is used for PSA/VPSA oxygen booster stations, hospital/medical oxygen filling, industrial gas cylinder filling, lab high-purity O₂ transfer, aerospace/breathing-oxygen backup and small gas-works filling rooms. The diaphragm principle separates oxygen from hydraulic oil and crankcase lubricant by one or more static metal membranes, so the gas path stays oil-free and contamination-controlled even at high discharge pressure. For oxygen, this isolation is the primary fire/combustion-control measure because concentrated O₂ under pressure can ignite oil, grease, particulates and incompatible non-metals.

Air cooling is practical for small and mid-power oxygen boosters, but at 90-250kW continuous cylinder-filling duty the thermal load, ambient temperature, stage count and required discharge pressure usually decide whether pure air cooling, forced-draft air cooling or air-cooled compressor plus supplementary heat rejection is acceptable. Large 250kW diaphragm stations are more often supplied as multiple medium-power skids than one giant air-cooled head.

Oxygen Diaphragm Reference By Power Band

 

Power Band

Typical Oxygen Filling Duty

Suction / Discharge

Planning Flow

Cooling Note

3-4kW

Small PSA boost, clinic/medical filling, lab O₂

0.3-0.4MPa(g) to 15MPa; 4-12Nm³/h sample

4-12Nm³/h at 15MPa sample

Air-cooled cabinet feasible for low duty

5-11kW

Single-bay cylinder filling, 10-15MPa medical/industrial

0.1-0.6MPa(g) to 10/15/20MPa

5-30Nm³/h depending on suction

Air-cooled OK for intermittent; water option for 20MPa continuous

15-30kW

PSA station boost to 15/20MPa, multiple manifolds

0.1-1.0MPa(g) to 15/20/23MPa

30-70Nm³/h sample range

Air-cooled possible; verify summer ambient and stage temperature

37-90kW

Regional O₂ filling, buffer storage, 15-23MPa continuous

0.1-2.0MPa(g) to 15/23/30MPa

70-200Nm³/h estimate by stage

Forced air or mixed cooling; water intercooling often preferred above 55-75kW

110-250kW

Central filling plant, multiple racks, 15-30MPa

0.1-3.0MPa(g) to 15/23/30MPa+

200-1000+Nm³/h by parallel skids

Usually multiple diaphragm skids; pure air-cooled only if duty/ambient allow, else water/combined cooling

Industrial diaphragm packages are documented from about 2kW to 150kW per reference drive range , with general GZ-type diaphragm frames 2.2-55kW and high-pressure industrial samples reaching 30-200kW at 6500-15000psig depending on flow . For 250kW oxygen filling, specify parallel 55-90kW skids or custom multi-cylinder diaphragm machines rather than assuming one air-cooled unit.

3kW-250kW AC Air-Cooled Oil-Free Stationary Diaphragm Compressor For Oxygen Cylinder Filling

Why Diaphragm For Oxygen Cylinder Filling

  • Oil-free gas path: metal diaphragm isolates O₂ from hydraulic oil; gas-side chamber uses no lubricating oil, reducing combustion risk and purity contamination.

  • High purity: all-wetted stainless construction, electropolished 316L/optional special alloy and metal/PTFE sealing support medical and high-purity oxygen when the whole train—piping, tank, valves, filters—is qualified.

  • Leak control: triple-layer diaphragm with rupture/alarm cavity detects primary membrane failure before gas mixes with hydraulics.

  • High pressure: single or multi-stage diaphragm can fill 10-23MPa industrial/medical cylinders and higher-pressure specialist cylinders; multi-stage with intercooling controls temperature rise.

  • Stationary station format: skid-mounted motor, PLC cabinet, receiver, dryer/filter, manifold and safety system for 24h filling duty.

Stage And Pressure Configuration

Oxygen bottle filling is usually divided by target cylinder pressure:

 

Target Cylinder Pressure

Suction Condition

Suggested Diaphragm Layout

10-15MPa / 100-150bar

PSA 0.3-0.6MPa(g)

2-stage air-cooled diaphragm; 3-15kW for small flow, 15-37kW for higher flow

15-20MPa / 150-200bar

PSA 0.4-1.0MPa(g) or low-pressure buffer

2-3-stage; intercooling required above approx 7-10MPa discharge ratio

20-23MPa / 200-230bar

PSA/buffer 0.5-2.0MPa(g)

3-stage with stage cooling; 15-55kW mid flow

30MPa+ / 300bar+

Low-pressure generator or cascade buffer

3-4-stage custom; usually water or combined cooling for continuous duty

35-70MPa specialist

Research/special cylinder

Custom multi-stage; air-cooled only for very low flow and verified thermal design

General diaphragm guidance gives single-stage ratio around 4:1-8:1 and recommends multi-stage above 25MPa. Oxygen discharge temperature must be kept low because high O₂ temperature increases ignition risk from oil residue, particles or incompatible materials; use interstage coolers, conservative ratios and alarm shutdown on over-temperature.

3kW-250kW AC Air-Cooled Oil-Free Stationary Diaphragm Compressors For Oxygen Cylinder Filling

Materials And Oil-Free Specification

Oxygen service requires strict material and cleanliness rules:

  • Wetted parts: 316L stainless as baseline; higher stages or corrosive/impurity conditions may use Inconel, Hastelloy or special alloy after gas-analysis review. All-gas-contact surfaces cleaned, degreased, oxide/particle-controlled.

  • Diaphragm: stainless multilayer or special-alloy multilayer with intermediate leak cavity; triple-membrane designs with rupture alarm are used for hazardous/high-purity gas.

  • Valves/seals: PTFE, PEEK or metal-to-metal validated for oxygen; avoid unknown elastomers, oils, greases and zinc/copper parts unless oxygen-compatibility documented.

  • Hydraulic system: separate from gas; use oxygen-compatible hydraulic fluid specification if any leakage path is possible; monitor diaphragm-cavity pressure for breach.

  • Purity: medical/PSA filling may target ≥99.5% O₂ in sample diaphragm packages ; high-purity/electronics grades require electropolish, orbital weld, particle/moisture analysis and validated ISO purity class.

  • Cleaning standard: oxygen-compatible degreasing, particulate removal, non-oil assembly, documented cleanliness level by pressure and purity.

Air-Cooled Oxygen Station Configuration

A complete stationary air-cooled oxygen filling station usually includes:

  1. Suction train — dust filter, moisture control, pressure regulator/buffer tank, O₂ analyzer, non-return safety.

  2. Diaphragm compressor — AC motor, VFD optional, air-cooled head/aftercooler/intercooler fans, multilayer diaphragm, oxygen-compatible valves.

  3. Discharge train — interstage/after coolers, safety relief per stage, check valves, oil-free receiver approved for O₂.

  4. Drying/filtration — refrigeration or adsorption dryer by dew point; particulate and bacteria/odor filters for medical; all O₂-clean housings.

  5. Filling manifold — multi-post cascade, pressure ramp control, individual cylinder isolation, excess-flow and relief.

  6. Control — PLC with suction/discharge pressure, stage temperature, flow, motor load, diaphragm-leak alarm, emergency stop, data logging.

  7. Safety — oxygen gas detection where required, ventilation permissive, explosion-protected electrical equipment by area classification, earthing/bonding, fire extinguishers, automatic isolation.

Sample small oxygen diaphragm units are offered 3-4kW, 4-12Nm³/h, 0.3-0.4MPa inlet, 15MPa outlet, air-cooled, 220/380/415/440V 50/60Hz. Larger GZ diaphragm frames list 2.2-55kW, 5-1000Nm³/h, air/water cooling and up to 70MPa depending on model.

3kW-250kW AC Air-Cooled Oil-Free Stationary Diaphragm Compressor For Oxygen Cylinders Filling

Electrical And VFD Planning

  • Voltage: small units 220/380/415/440V 50/60Hz; mid/large 380-690V three-phase AC depending on site and motor power.

  • VFD benefit: stable pressure ramp for cylinder filling, lower inrush, better part-load efficiency when PSA output or fill demand varies, softer start for air-cooled fans and larger motors.

  • Oxygen area electrical: use explosion-protected motors/control per classified zone; diaphragm OEMs offer CT4/ATEX-type ratings for hazardous gas packages. Oxygen is strong oxidizer; even if not flammable alone, electrical equipment, fans and switches must follow the station hazard study.

  • Cooling power: air-cooled oxygen diaphragm draws additional fan power; at 90-250kW total station load, evaluate ambient 40-50°C derating, intake air recirculation and compressor-room ventilation before fixing pure air-cooled design.

  • Grounding/bonding: all O₂ pipes, receivers, manifolds and skids bonded; no oil/grease on joints; spark-safe tools in maintenance.

Sizing Method For Oxygen Cylinder Filling

  1. Define oxygen source: PSA purity and pressure, liquid vaporizer pressure, or low-pressure buffer. PSA 0.3-0.6MPa(g) is common for small diaphragm fillers.

  2. Define cylinder type and target pressure: 15MPa medical/industrial, 20-23MPa high-pressure industrial, 30MPa+ specialist.

  3. Calculate required Nm³/h: cylinders × water volume × target pressure ÷ fill time ÷ recovery factor. Add 10-15% capacity margin.

  4. Convert to compressor FAD at suction condition; diaphragm selection uses Nm³/h, not only discharged volume.

  5. Select stages by pressure ratio and temperature: 10-15MPa from PSA often 2-stage; 20-30MPa often 3-stage; 30MPa+ often 3-4-stage with intercooling.

  6. Choose cooling: air-cooled for 3-55kW light/ambient-controlled rooms; forced air or mixed for 55-90kW; water/combined for 110-250kW continuous or hot climate.

  7. Choose materials by purity: 316L standard, electropolish for high purity, special alloy only if impurity/corrosion data requires.

  8. Add drying/filtration to required dew point and ISO purity class; medical filling may need bacterial/odor control and validated cleanliness.

  9. Add safety system: stage relief, burst disk where specified, O₂ detection/ventilation, diaphragm-leak alarm, PLC ESD, fire plan.

  10. Request factory FAT on oxygen or certified inert gas at actual suction/discharge, with flow, temperature, leak and electrical verification.

Example Station Sizes

  • Clinic/medical small filling: 3-4kW diaphragm, 0.3-0.4MPa PSA suction, 15MPa discharge, 4-12Nm³/h, air-cooled, 316L, PLC, single 4-10 post manifold.

  • Hospital PSA boost: 5-11kW, 0.4-0.6MPa suction, 15-20MPa, 10-30Nm³/h, air-cooled or water-cooled by runtime, dryer to medical dew point, cascade filling.

  • Industrial gas shop: 15-37kW, 0.5-1.0MPa suction, 15-23MPa, 30-100Nm³/h, 2-3-stage, forced air or water intercooling, multiple manifolds.

  • Regional O₂ plant: 55-90kW × 2-3 skids, buffer 1-2MPa, 20-23MPa, parallel filling racks, central dryer/filter, PLC SCADA, ventilation and explosion-protected electrical.

  • 250kW central filling: typically 3-5 diaphragm skids, 15-30MPa, 200-1000+Nm³/h combined, staged cooling, bulk O₂ buffer, automated cascade, full safety interlock—pure air-cooled only if site ambient, fan capacity and redundancy are proven.

Maintenance Program

 

Item

Small 3-11kW Air-Cooled

15-90kW Station

110-250kW Multi-Skid Plant

Daily check

Pressure, stage temp, flow, alarms

Add dryer dew point, fan status, manifold pressure

Add SCADA trends, O₂ detection, cooling-air temp

Diaphragm inspection

By hours/leak-cavity differential

Shorter interval for 15-23MPa continuous

Per skid; spare heads/diaphragms in stock

Valves/filters

Inspect by differential/purity

More frequent for PSA dust/moisture

Automated differential alarms, planned overhaul

Cooling/air path

Clean fins, fans, intake screen

Pressure-wash condenser/radiator per dust load

Monitor ambient recirculation, fan redundancy

Hydraulic oil

Sample/filter per OEM; oxygen-compatible spec

Same, stricter for high pressure

Central log, condition monitoring

Drying/filtration

Replace per medical/industrial class

More frequent in humid climate

Validated ISO 8573-style/medical purity audit

Safety devices

Relief/burst test, ESD test

O₂ detection calibration, ventilation trip

Full HAZOP review, periodic ESD drill

Cleaning/oxygen integrity

Re-clean piping on open maintenance

Strict O₂-clean procedure for any opened wetted part

Documented decontamination, inert purge, permit

Diaphragm life depends on pressure ratio, temperature, suction stability and material finish; references cite around 8,000-10,000h for some diaphragm programs, but oxygen high-pressure duty should be scheduled conservatively.

Safety And Compliance Checklist

  • Oil-free confirmation: no lubricated gas contact; hydraulic oil isolated by diaphragm; diaphragm-breach alarm.

  • Material certification: 316L/Inconel/Hastelloy wetted parts, oxygen-clean procedure, no oil/grease residue.

  • Combustion control: conservative stage temperature, intercooling, particle control, non-spark fittings, anti-static bonding.

  • Explosion protection: classified electrical equipment for oxygen-enriched/leak zones; CT4/ATEX/IECEx as applicable.

  • Purge/commissioning: inert gas purge before oxygen; triple inert purge is used by some diaphragm OEMs for oxygen/hydrogen service.

  • Pressure protection: stage relief valves, final relief, burst disks where specified, overpressure ESD.

  • Leak/ventilation: O₂ detectors where enrichment possible, forced ventilation, safe vent path, no confined accumulation.

  • Standards/documents: ISO 9001 manufacturer system; pressure-equipment compliance per destination such as CE/PED/ASME; material certificates; FAT/ITP; oxygen-clean report; electrical Ex certificates; PLC alarm/trip setpoints.

Frequently Asked Questions

Is air-cooled enough for 250kW oxygen filling?

Not automatically. Small 3-11kW and many 15-55kW oxygen diaphragm fillers can be air-cooled in climate-controlled rooms. For 90-250kW continuous 15-30MPa filling, heat rejection is large; specify forced-draft air, mixed air/water intercooling, or water-cooled skids. Many large diaphragm systems use water cooling for high-pressure stages even if the package is advertised stationary/air-assisted.

What flow can 3kW deliver to 15MPa oxygen cylinders?

Sample 3-4kW oxygen diaphragm units are listed at 4-12Nm³/h from 0.3-0.4MPa suction to 15MPa, air-cooled. Actual output depends on suction pressure, suction temperature, PSA purity, stage cooling and altitude; request factory FAD at 15MPa, not at low discharge pressure.

Do oxygen diaphragm compressors need water cooling?

Not always. Low-pressure 10-15MPa small fillers can be air-cooled. Multi-stage 20-30MPa, high ambient, 24h duty or large flow usually benefit from water or combined cooling to control discharge temperature and diaphragm stress.

What material is standard for oxygen diaphragms?

316L stainless wetted parts are common; electropolished 316L for high purity; Inconel/Hastelloy or special alloy for aggressive impurities, very high stage temperature or customer specification. All materials must be oxygen-clean and grease-free.

Can one 250kW diaphragm machine fill all cylinders?

For central plants, parallel skids are safer and more redundant than one huge machine. Multiple 55-90kW air-cooled/water-cooled diaphragm skids allow staged maintenance, better part-load control and separate medical/industrial manifolds.

What PLC safety functions are required?

Suction low-pressure alarm, discharge over-pressure trip, stage over-temperature trip, diaphragm-leak alarm, motor overload/over-current, emergency stop, dryer/filter differential, oxygen detection/ventilation interlock where required, fill-manifold pressure ramp and data logging.

Is VFD necessary for oxygen cylinder filling?

Not mandatory, but beneficial. PSA output and fill demand often vary; VFD ramps pressure, reduces inrush on AC supply, improves part-load efficiency and protects air-cooled thermal balance. Fixed-speed is acceptable for steady constant-flow filling.

What should be requested from suppliers for quotation?

Oxygen purity and source pressure, suction temperature, target cylinder pressure, Nm³/h per shift, daily filling hours, ambient/altitude, cooling preference, medical or industrial purity class, material requirement, Ex zone, dryer dew point, manifold size, voltage/frequency, PLC/SCADA requirement, FAT gas, oxygen-clean standard, relief/ventilation design and commissioning scope.

A 3kW-250kW AC air-cooled oil-free stationary diaphragm oxygen filling system should be specified by duty band rather than by power alone: 3-11kW air-cooled cabinets for clinic/PSA small filling, 15-55kW forced-air or mixed-cooling skids for industrial manifolds, and 90-250kW parallel diaphragm skids with staged cooling, 316L/electropolished oxygen-clean wetted paths, multilayer leak-alarm diaphragms, PLC safety interlocks and explosion-protected electrical controls. For 15-23MPa medical/industrial cylinders this gives oil-free, low-contamination, stable-pressure filling; for 30MPa+ or 250kW central plants, multi-stage intercooling and redundant skids are usually safer than a single air-cooled machine.


Tags:

Contact Us

unionaircompressor.com

Mobile:8618267307420

QQ:503155169

Mail:503155169@qq.com

Add:Hongxing Road, Economic and Technological Development Zone, Jiaxing City, Zhejiang Province,China

Order:3kW-250kW AC Oil-Free Diaphragm Compressor For Oxygen

Related / RELATED PRODUCTS