Welcome to unionaircompressor.com
Complete Air Compressor Solutions Starts HereUnion Air Compressor丨Screw, Piston & Industrial Air Compressors Worldwide
WhatsApp:8618267307420

Screw Air Compressor 2980r/min 7.5KW 78±2dB(A) 380V 50Hz

Products Details

Single Stage Power Frequency Screw Air Compressor 2980r/min 7.5KW 78±2dB(A) 380V 50Hz: The Complete Technical & Buying Guide

A single stage power frequency screw air compressor rated at 2980 r/min, 7.5KW (10HP), 78±2 dB(A), and 380V 50Hz​ represents one of the most widely deployed workhorses in the global small-to-medium industrial compressed air market. It answers a very specific engineering and commercial brief: deliver reliable, continuous-duty screw compression at a mainstream pressure of 7–8 bar (102–116 PSI), run on the universally available three-phase 380V 50Hz industrial grid, and do so at the lowest possible capital cost per CFM. Without variable frequency drive complexity, without two-stage compression overhead, and without premium acoustic enclosures, this configuration puts proven screw technology within reach of workshops, fabrication units, automotive service centers, and light manufacturing lines that need steady air—not bells and whistles.

This guide consolidates verified market specifications, single-stage vs. two-stage trade-offs, 380V 50Hz electrical requirements, and maintenance protocols to help dealers, procurement managers, and shop owners make a confident, data-driven decision.


The Engineering Logic Behind the Single-Stage Power Frequency Configuration

Integrating four defining attributes—single-stage screw airend, fixed-speed (power frequency) motor, 2980 r/min rotor speed, and 380V 50Hz three-phase power—creates a synergy that prioritizes reliability and value:

  • Single-stage screw airend: A single set of precision-meshed male and female rotors compresses incoming air to the target pressure (typically 7–8 bar) in one continuous action. This is the simplest, most proven, and most cost-effective screw architecture, with airend service life rated at 20,000–40,000 hours .

  • 2980 r/min motor speed: In 50Hz markets, a 2-pole induction motor spins at approximately 2980–3000 RPM. This high motor speed drives the screw rotor directly (direct-coupled) or via a 1:1 gear set, delivering full-rated displacement efficiently. The 2980 RPM figure is the standard electrical synchronous-approximation speed for 2-pole 50Hz motors.

  • Power frequency (fixed-speed) operation: The motor runs at constant speed whenever the pressure switch commands "load." This eliminates the cost and complexity of a variable frequency drive (VFD) inverter, reducing upfront price by 20–40% versus PM VSD equivalents while maintaining bulletproof simplicity .

  • 380V 50Hz three-phase power: The global standard for light-industrial grids across Europe, Asia, Africa, and the Middle East. A 7.5KW load draws approximately 15A per phase—well within a standard 25A three-phase circuit.

The result is a compressor that starts up, runs at full displacement until the tank reaches cut-out pressure, unloads, and repeats—day in, day out, with minimal electronic complexity to fail.


Screw Air Compressor 2980r/min 7.5KW 78±2dB(A) 380V 50Hz

Market Specification Benchmarks: What 7.5KW Single-Stage Power Frequency Actually Delivers

Aggregating verified manufacturer data across global suppliers reveals the dominant specification cluster for this configuration:

 

Specification

Typical 7.5KW Single-Stage Power Frequency

Motor Power​

7.5 KW (10 HP)

Voltage / Phase / Frequency​

380V / 3φ / 50Hz (220V, 415V, 440V optional)

Working Pressure​

7–8 bar (102–116 PSI); 10–13 bar optional

Free Air Delivery (FAD)​

1.0–1.2 m³/min (35–42 CFM) at 8 bar

Noise Level​

62–78 dB(A) (open-frame: 75–78 dB(A); enclosed: 62–68 dB(A))

Motor Speed​

2980 r/min (2-pole, 50Hz)

Compression Stage​

Single-stage

Drive Method​

Direct drive (1:1 coupling) or belt drive

Outlet Diameter​

G1/2" (DN15)

Weight​

190–280 kg (compressor only); 380 kg (with 250L tank + dryer)

Dimensions (mm)​

800–900 × 650 × 830–1000 mm (compressor only)

Discharge Temperature​

Ambient +15°C

Oil Content in Air​

≤3 ppm

Airend Service Life​

20,000–40,000 hours

Motor Protection​

IP23 or IP54; Class F insulation

Lubricant Capacity​

4 L

Starter Type​

Direct-on-line (DOL) or Star-Delta

Control Mode​

ON/OFF load/unload via pressure switch + PLC controller

Screw Air Compressors 2980r/min 7.5KW 78±2dB(A) 380V 50Hz

Data synthesized from Hande HD-7D5 (7.5KW/8bar/1.0 m³/min/2980 rpm/68±2 dB(A)/250L tank/integrated dryer) , Kingair KA-10D (7.5KW/7bar/1.2 m³/min) , MDW fixed-speed series (7.5KW/0.7–1.2 MPa/62±5 dB(A)) , Wallboge BG10A (7.5KW/8bar/1.1 m³/min/39 CFM) , AIRSTONE AS-10HB (7.5KW/8bar/1.1 m³/min) , and ZAKF ZA-10 (7.5KW/8bar/1.1 m³/min/≤68 dB(A)) .

Critical insight: The typical 7.5KW single-stage power frequency compressor delivers 1.0–1.2 m³/min (35–42 CFM) at 8 bar. This is the sweet spot for 3–6 pneumatic workstations in an automotive workshop, woodworking shop, metal fabrication unit, or small assembly line. At 7 bar, displacement rises to 1.2 m³/min; at 10 bar, it drops to 0.9–1.0 m³/min —a direct consequence of the fixed-speed motor's constant displacement vs. pressure relationship.

On the 78±2 dB(A) noise level: Open-frame, non-acoustically-enclosed 7.5KW power frequency screw compressors typically register in the 75–78 dB(A)​ range at 1 meter, as specified in this product title. Units with integrated acoustic enclosures or cabinet designs achieve 62–68 dB(A) . The 78±2 dB(A) figure indicates an industrial open-frame configuration intended for plant rooms, compressor houses, or outdoor/semi-enclosed installations where noise is managed at the room level rather than at the machine level.


Why Single-Stage? The Trade-Off vs. Two-Stage Screw

Understanding when single-stage is the correct choice—and when two-stage is warranted—is essential for informed procurement:

 

Parameter

Single-Stage (This Configuration)

Two-Stage Screw

Compression Steps​

One (single rotor set)

Two (low-pressure + high-pressure rotors with intercooler)

Compression Ratio per Stage​

6–8:1 (entire load on one rotor)

3–4:1 per stage (split across two)

Discharge Temperature at 8 bar​

85–105°C

75–85°C (after inter-stage cooling to 40–50°C)

Specific Power (kW per m³/min)​

6.8–7.8

5.5–6.2 (15–25% more efficient)

Airend Service Life​

20,000–40,000 hours

40,000–60,000 hours

Noise Level​

68–78 dB(A)

62–72 dB(A)

Typical Pressure Range​

0.7–1.0 MPa (up to 1.6 MPa max)

0.8–4.0 MPa (stable at 1.6–3.0 MPa)

Capital Cost​

Baseline (lowest)

20–40% premium over single-stage

Best-Fit Applications​

Woodworking, automotive service, general workshops, 0.7–1.0 MPa continuous duty

High-pressure bottling, chemical transfer, electronics high-pressure cleaning, multi-shift >8h/day continuous heavy load

Energy Savings Payback​

N/A

12–18 months (only for >75KW or multi-shift operations)

Data from Seize Air , Saman Machinery , and China Compressor .

Key takeaway: For a 7.5KW compressor operating at 7–8 bar in a single-shift or intermittent-duty workshop, single-stage is definitively the correct choice. The 15–25% energy savings of two-stage design only justifies its capital premium at higher power ratings (≥75KW) or in continuous multi-shift operations where energy costs dominate . At 7.5KW, the simplicity, lower upfront cost, and proven reliability of single-stage far outweigh the marginal efficiency gain of two-stage architecture.


Screws Air Compressors 2980r/min 7.5KW 78±2dB(A) 380V 50Hz

Application Matching: CFM, Pressure & Duty by Use Case

Selecting the right configuration depends entirely on matching air delivery to application demand:

 

Application

Operating Pressure

Air Demand

Fit Assessment

Automotive workshop (3–4 lifts, impact wrenches, inflators)​

7–8 bar

25–40 CFM (peak)

Ideal​ — 35–42 CFM capacity with margin

Woodworking shop (sanders, nailers, spray guns)​

6–8 bar

20–35 CFM (concurrent)

Ideal​ — handles orbital sanders + HVLP spray

Metal fabrication (plasma cutting assist, pneumatic tools)​

7–8 bar

30–40 CFM

Ideal​ — steady 8 bar supply

Small assembly line (actuators, valves, blowing)​

6–7 bar

20–35 CFM

Ideal​ — continuous-duty screw excels

Plastic injection molding (mold clamping, ejection)​

6–8 bar

25–40 CFM

Ideal​ — 2980 r/min fixed-speed matches steady demand

Textile mill (jet loom air supply)​

7–8 bar

30–45 CFM

Good​ — borderline for multiple looms

Food & beverage packaging (pneumatic filling, sealing)​

6–8 bar

20–35 CFM

Ideal​ — with downstream filtration

Printing industry (sheet-fed press air, cleaning)​

6–8 bar

15–30 CFM

Ideal​ — low-to-moderate demand

4S shop (vehicle service, tire shop, body shop)​

7–8 bar

25–40 CFM

Ideal​ — industry-standard configuration

Mold industry (blowing, pneumatic clamping)​

7–8 bar

20–35 CFM

Ideal​

Laboratory instrument supply (with dryer + filtration)​

7–8 bar

10–25 CFM

Viable​ — requires integrated dryer + 0.01μm filter

Glass & sign production (light blasting, pneumatic tools)​

6–8 bar

20–35 CFM

Ideal​

Construction site (mobile pneumatic tools)​

7–8 bar

25–40 CFM

Viable​ — with wheeled tank option

Sizing rule: Calculate the CFM demand of all tools running simultaneously during peak production, apply a 0.7 simultaneous-usage factor, then add 20–30% safety margin. For a workshop running an impact wrench (6 CFM) + random orbital sander (8 CFM) + HVLP spray gun (15 CFM) concurrently, peak demand is 29 CFM × 0.7 = 20.3 CFM, +30% margin = 26.4 CFM. The 7.5KW unit's 35–42 CFM capacity covers this with ample headroom.


380V 50Hz: The Global Industrial Power Standard

Three-phase 380V 50Hz is the dominant industrial power standard across Europe, Asia, Africa, and the Middle East. For the 7.5KW single-stage power frequency compressor, this brings decisive advantages:

  • Lower current draw: At 380V 3φ, a 7.5KW compressor draws approximately 15A per phase. Compare this to single-phase 220V, where the same 7.5KW would draw 34A—nearly 2.3× the current, requiring much heavier wiring .

  • Balanced load: Three-phase power distributes the electrical load evenly across three conductors, eliminating the neutral current imbalance and reducing transmission losses.

  • Direct-on-line (DOL) or Star-Delta starting: Fixed-speed compressors use simple electromechanical starters. Star-Delta starting (as noted in product literature ) reduces inrush current to 30% of DOL values, protecting the electrical grid and motor windings.

  • Global compatibility: 380V/50Hz/3φ is standard; 220V, 415V, and 440V variants are available as options without major redesign.

  • No VFD complexity: Power frequency operation means no inverter electronics to fail, no harmonic distortion concerns, and no expensive variable-frequency motor requirements. Mean time between failures (MTBF) is maximized.

Electrical specification:

  • Circuit requirement: Dedicated 3-phase 380V 50Hz supply, 25A breaker per phase, 4mm² copper wiring

  • Earthing: Proper TN-S or TN-C-S earthing per local electrical code

  • Starting method: Star-Delta (recommended for 7.5KW to limit inrush) or DOL

  • Motor protection: IP54 enclosure, Class F insulation, thermal overload relays on all three phases


Engineering the 2980 r/min Fixed-Speed Operation

The 2980 r/min figure is not arbitrary—it is the direct consequence of 2-pole induction motor physics at 50Hz:

Synchronous Speed Calculation:

  • Synchronous speed = (120 × frequency) / number of poles

  • = (120 × 50) / 2 = 3000 RPM (theoretical synchronous)

  • Actual rotor speed = 3000 − slip ≈ 2980 RPM​ (typical 2-pole motor slip: 0.5–1%)

Why 2-pole / 2980 RPM?

  • Screw airends are optimally efficient at rotor speeds between 3000–6000 RPM depending on rotor diameter and lobe profile

  • A 2-pole motor at 2980 RPM directly couples to the airend without speed reduction, achieving 100% transmission efficiency

  • Higher pole-count motors (4-pole at 1480 RPM) would require speed-increasing gears, adding complexity and efficiency loss

  • The 2980 RPM direct-drive configuration minimizes mechanical parts, reduces maintenance points, and maximizes reliability

Operational Characteristics:

  • Constant displacement: At fixed motor speed, the compressor delivers constant volumetric flow (1.0–1.2 m³/min) regardless of demand

  • Load/Unload cycling: When tank pressure reaches cut-out (e.g., 8.5 bar), the compressor unloads (intake valve closes, motor continues spinning) until pressure drops to cut-in (e.g., 6.5 bar), then reloads

  • Unloaded power consumption: 15–25% of rated power during unload phase—this is the primary energy inefficiency of fixed-speed vs. VSD

  • Duty cycle: Suitable for 60–100% duty; for variable demand <60%, VSD would be more efficient


The 78±2 dB(A) Noise Profile & Plant Room Strategy

At 78±2 dB(A), this configuration falls into the "industrial open-frame" noise category. Proper deployment strategy:

1. Dedicated compressor room: Install in a separate plant room or outdoor enclosure with acoustic treatment (foam panels, baffles) to reduce ambient noise in the workspace to <70 dB(A).

2. Vibration isolation: Rubber anti-vibration mounts beneath the compressor feet reduce structure-borne noise transmission by 5–8 dB(A) .

3. Intake silencer: Reactive silencers on the air intake attenuate broadband intake noise by 10–15 dB.

4. Distance attenuation: At 3 meters from the unit, sound pressure level drops to approximately 68–70 dB(A)—below the 85 dB(A) occupational exposure threshold.

5. Alternative: acoustically enclosed variant: If the compressor must be installed in or adjacent to the workspace, choose an enclosed cabinet version achieving 62–68 dB(A) —at a 10–20% cost premium.

Comparison to alternatives:

 

Configuration

Noise Level

Relative Cost

Best Installation

Open-frame 7.5KW (78±2 dB(A))​

76–80 dB(A)

Baseline

Plant room, outdoor, enclosed space

Enclosed cabinet 7.5KW (62–68 dB(A))​

62–68 dB(A)

+10–20%

In-workshop, adjacent to work area

VSD enclosed 7.5KW (63–66 dB(A))​

63–66 dB(A)

+30–50%

In-workshop, variable demand

Two-stage 7.5KW (62–72 dB(A))​

62–72 dB(A)

+20–40%

High-pressure applications


Integrated Options: Tank, Dryer & Filtration

While the base compressor is often sold standalone, the complete industrial air system typically includes:

1. Receiver Tank (200–500L)

  • 200L: Compact footprint, suitable for 1–2 workstation workshops

  • 250L: Standard configuration (as in Hande HD-7D5)

  • 300–500L: Maximum buffer for multi-station operations, reduces motor cycling by 30–40%

2. Refrigerated Air Dryer

  • Integrated dryers (e.g., FL01-HD: 1.2 m³/min capacity, 0.37KW, 220V/50Hz) achieve pressure dew point ≤ +3°C

  • Critical for preventing moisture in air lines, protecting pneumatic tools, and ensuring finish quality in spray applications

3. Filtration Chain

  • Intake filter​ (3–5 μm): Removes ambient dust before compression

  • Coalescing filter​ (0.01 μm): Removes oil aerosols (discharge oil content ≤3 ppm )

  • Particulate filter​ (0.01 μm): Final cleanup for sensitive applications

  • Activated carbon​ (optional): For hydrocarbon vapor adsorption in food, pharma, or lab applications

4. Integrated 4-in-1 Packages

Many manufacturers offer the compressor + tank + dryer + filtration as a single integrated skid (as in Hande HD-7D5: 1430×710×1470mm, 380 kg )—reducing installation cost, footprint, and leak points.


Maintenance: Simple But Disciplined

The single-stage power frequency screw design is among the simplest to maintain:

 

Interval

Task

Daily​

Drain tank condensate; verify pressure gauge; check for abnormal noise/vibration

Weekly​

Inspect intake filter; check belt tension (if belt-driven); verify electrical connections

Monthly​

Test safety relief valve; check oil level; monitor discharge temperature

Every 500 Hours​

First oil change + oil filter + air filter (break-in service)

Every 3,000 Hours​

Replace lubricating oil (4L capacity), oil filter, air filter element, oil separator

Every 3,000 Hours​

Inspect airend for wear; check coupling alignment; clean oil cooler fins

Every 20,000–40,000 Hours​

Major airend overhaul or replacement

Maintenance intervals from Hande HD-7D5 specification ; general screw compressor best practices.

Critical insight: The single greatest maintenance mistake is neglecting oil changes. With discharge temperatures of 85–105°C , oil degrades faster than in two-stage designs (which run cooler). Strict adherence to the 3,000-hour oil change interval extends airend life from the lower bound (20,000 hours) toward the upper bound (40,000 hours) .


Specification Comparison: How 7.5KW Single-Stage Power Frequency Units Stack Up

To provide a realistic competitive picture without naming brands, here's how representative units compare:

 

Parameter

Open-Frame Standard

Enclosed Cabinet

Integrated 4-in-1

Power​

7.5 KW (10 HP)

7.5 KW (10 HP)

7.5 KW (10 HP)

FAD at 8 bar​

1.0–1.2 m³/min

1.0–1.2 m³/min

1.0–1.2 m³/min

Pressure​

7–8 bar (10–13 bar opt.)

7–8 bar

7–8 bar

Noise​

75–78 dB(A)

62–68 dB(A)

62–68 dB(A)

Tank​

None (standalone) or 200–300L

None or 250L

250–300L integrated

Dryer​

Optional external

Optional external

Integrated refrigerated (≤+3°C)

Filtration​

External

External

Integrated 5-stage

Drive​

Direct drive

Direct drive

Direct drive

Motor Speed​

2980 r/min

2980 r/min

2980 r/min

Voltage​

380V/3φ/50Hz

380V/3φ/50Hz

380V/3φ/50Hz

Weight​

190–200 kg

200–250 kg

380 kg (with 250L tank + dryer)

Dimensions (mm)​

890×650×830

900×650×850

1430×710×1470

Outlet​

G1/2"

G1/2"

Rp3/4"

Motor Protection​

IP23 or IP54

IP54

IP54

Starter​

DOL or Star-Delta

Star-Delta

Star-Delta

Best For​

Plant room, outdoor, dedicated compressor house

In-workshop installation

Turnkey installation, minimal piping

Price Positioning​

Entry-level (lowest)

Mid-range (+10–20%)

Premium (+30–50%)

Specifications aggregated from Hande , Kingair , MDW , Wallboge , AIRSTONE , ZAKF , and Keepwin .

Selection takeaway: For plant rooms and outdoor installations where noise is managed at the room level, the Open-Frame Standard​ tier (75–78 dB(A), 1.0–1.2 m³/min, standalone or with external tank) delivers the lowest capital cost. For in-workshop installations requiring lower noise, the Enclosed Cabinet​ tier (62–68 dB(A)) adds acoustic enclosure at modest premium. For turnkey deployments wanting zero installation hassle, the Integrated 4-in-1​ tier combines compressor + 250L tank + refrigerated dryer + filtration in a single 380 kg skid.


Installation & Setup Best Practices

1. Electrical Supply

Verify 380V ±10% / 50Hz / 3-phase supply with proper earthing. Install a dedicated 25A 3-phase circuit breaker. For Star-Delta starting, ensure correct wiring sequence (U/V/W phase order) to avoid reverse rotation.

2. Foundation & Placement

Position on a level concrete floor (100mm+ thickness) with rubber anti-vibration mounts. Maintain minimum 12 inches (300mm) clearance on all sides for ventilation and service access. For 78±2 dB(A) open-frame units, install in a dedicated compressor room with acoustic treatment.

3. Ambient Conditions

Operating ambient temperature: -5°C to +45°C . Ensure adequate ventilation—the compressor rejects 7–10KW of heat into the room. For enclosed spaces, calculate ventilation requirement: minimum 1500–2000 m³/h air exchange.

4. Condensate Management

Install automatic drain valve at tank bottom. Route condensate to neutralized drain per environmental regulations—compressed air condensate contains traces of lubricant requiring proper disposal.

5. Piping

Main trunk line: minimum 3/4" ID galvanized steel, aluminum, or rated polymer. Install service isolation valve at compressor outlet, then branch to workstations with secondary regulators and point-of-use filters. Slope main lines 1:100 toward drain legs at low points.

6. Pressure Setting

Set cut-in/cut-out pressure differential to 2 bar (e.g., 6.5 bar cut-in, 8.5 bar cut-out). This optimizes motor cycling frequency and reduces unloaded power consumption. Narrower differentials cause excessive cycling; wider differentials strain the motor.

7. Dryer Commissioning

If integrated or external refrigerated dryer is installed, verify pressure dew point ≤ +3°C before connecting critical applications. For spray painting or instrument air, add a desiccant dryer to achieve ≤ -40°C dew point.


Troubleshooting Common Issues

Problem: Compressor fails to reach 8 bar target pressure

  • Cause: Worn airend rotors (if >20,000 hours), clogged intake filter, or air leak in piping

  • Solution: Replace air intake filter (3,000-hour interval); pressure-test all connections; if unit exceeds 20,000 hours, schedule airend inspection

Problem: Excessive energy consumption

  • Cause: Fixed-speed operation under variable demand; excessive unloaded running time

  • Solution: If demand varies >30% across the day, upgrade to VSD compressor (30–50% energy savings); otherwise, optimize cut-in/out differential and add larger tank (300–500L) to reduce cycling

Problem: Compressor overheats and shuts down

  • Cause: Blocked oil cooler fins, degraded lubricant (past 3,000-hour interval), or ambient temperature >45°C

  • Solution: Clean oil cooler fins with compressed air; change lubricant immediately; improve ventilation; verify ambient temperature

Problem: Oil carryover in air line exceeds 3 ppm

  • Cause: Failed oil separator (if >3,000 hours), overfilled oil reservoir, or excessive discharge temperature

  • Solution: Replace oil separator element; verify oil level at sight glass midpoint; check discharge temperature (should be ≤ambient+15°C)

Problem: Unusual noise or vibration developing

  • Cause: Worn coupling, misaligned direct drive, or deteriorated anti-vibration mounts

  • Solution: Inspect coupling for wear; verify rotor alignment; replace rubber isolation mounts

Problem: Motor fails to start

  • Cause: Phase loss, thermal overload tripped, or incorrect voltage

  • Solution: Verify 380V ±10% across all three phases; reset thermal overload; check star-delta timer; confirm proper earthing


Frequently Asked Questions

Q1: Is 78±2 dB(A) too loud for my workshop?

At 78±2 dB(A), the open-frame unit requires installation in a dedicated plant room, outdoor enclosure, or semi-enclosed compressor house. At 1 meter distance, 78 dB(A) is comparable to a busy restaurant or a vacuum cleaner. With a plant room and acoustic treatment, workspace noise stays below 70 dB(A). If you must install in or adjacent to the workspace, choose an enclosed cabinet version achieving 62–68 dB(A) .

Q2: Can a 7.5KW single-stage power frequency compressor support my automotive workshop?

Yes. At 35–42 CFM (1.0–1.2 m³/min) at 8 bar , the unit supports 3–4 vehicle lifts running impact wrenches, tire inflators, and a small spray gun concurrently. This is the industry-standard configuration for 4S shops and independent automotive service centers .

Q3: What's the realistic lifespan of a 7.5KW single-stage screw compressor?

Airend service life is rated at 20,000–40,000 hours​ . With disciplined maintenance (oil and filter changes every 3,000 hours), expect 10–15 years of reliable service in typical single-shift workshop operation. The motor and electrical components typically outlast the airend.

Q4: Why choose single-stage over two-stage at 7.5KW?

Two-stage screw compressors achieve 15–25% better energy efficiency and 40,000–60,000 hour airend life, but the capital premium only pays back within 12–18 months at ≥75KW or in continuous multi-shift operations . At 7.5KW single-shift, single-stage's lower upfront cost, simplicity, and proven reliability make it the definitively correct choice.

Q5: Is 380V 50Hz power sufficient, or do I need special electrical infrastructure?

380V 3-phase 50Hz is the global industrial standard. At 7.5KW, the compressor draws approximately 15A per phase —requiring only a dedicated 25A 3-phase circuit with 4mm² wiring. No special infrastructure needed.

Q6: What air delivery should I expect at different pressures?

At 7 bar: 1.2 m³/min (42 CFM). At 8 bar: 1.0–1.1 m³/min (35–39 CFM). At 10 bar: 0.9 m³/min (32 CFM). At 13 bar: 0.7 m³/min (25 CFM) . The fixed-speed motor delivers constant displacement; higher pressure reduces FAD due to thermodynamic effects.

Q7: How critical is the refrigerated dryer for my applications?

For spray painting, pneumatic instrumentation, and moisture-sensitive processes, a refrigerated dryer achieving ≤ +3°C dew point is mandatory. Without it, condensate forms in air lines, causing fisheye defects in paint, rust in pneumatic tools, and inconsistent actuator performance. Integrated dryers (e.g., 0.37KW, 1.2 m³/min capacity) handle the full output of a 7.5KW compressor .

Q8: What's the difference between power frequency (fixed-speed) and VSD compressors?

Fixed-speed compressors run at constant 2980 r/min, delivering constant displacement and cycling load/unload to match demand. VSD (variable speed drive) compressors modulate motor speed to exactly match air demand, reducing unloaded power consumption by up to 70% and delivering 30–50% total energy savings under variable demand . For steady-demand applications (e.g., continuous production lines), fixed-speed is more cost-effective. For variable-demand workshops, VSD pays back within 12–24 months.

Q9: How important is the 2980 r/min speed?

2980 r/min is the natural 2-pole motor speed at 50Hz. Direct coupling to the screw airend achieves 100% transmission efficiency with no belts, gears, or speed multipliers to fail . This is the optimal speed for 7.5KW-class screw airends, balancing displacement, efficiency, and airend longevity.

Q10: What maintenance is absolutely non-negotiable?

Oil and oil filter change every 3,000 hours (first change at 500 hours) . Air filter replacement every 3,000 hours. Oil separator replacement every 3,000 hours. Daily tank draining. These four tasks alone extend airend life from 20,000 to 40,000 hours.

Q11: Can I run the compressor outdoors?

Yes, with a weather-protective enclosure. Operating ambient range is -5°C to +45°C . Below -5°C, the lubricant thickens and starting torque increases; above 45°C, discharge temperature exceeds safe limits. Outdoor installation in moderate climates with a ventilated enclosure is common.

Q12: What's the oil content in the discharged air, and is it suitable for food/pharma?

Discharge oil content is ≤3 ppm​ —technically "oil-lubricated," not "oil-free." For food contact, pharmaceutical, or breathing air applications, downstream coalescing + activated carbon + 0.01 μm filtration is mandatory, and ISO 8573-1 Class 1 (≤0.01 mg/m³) compliance requires verification with integrated treatment. For non-contact industrial use, ≤3 ppm is acceptable with basic filtration.


Final Selection Framework

When specifying a single stage power frequency screw air compressor rated 2980 r/min, 7.5KW, 78±2 dB(A), 380V 50Hz, prioritize in this order:

  1. Free Air Delivery​ — 1.0–1.2 m³/min (35–42 CFM) at 8 bar; size to 130% of peak simultaneous demand

  2. Working pressure​ — 7–8 bar standard; 10–13 bar optional for higher-pressure tools

  3. Noise management​ — 78±2 dB(A) open-frame requires plant room; choose enclosed 62–68 dB(A) for in-workshop placement

  4. Motor speed​ — 2980 r/min (2-pole, 50Hz) direct-coupled for 100% transmission efficiency

  5. Voltage compatibility​ — 380V/3φ/50Hz standard; 220V/415V/440V options available

  6. Single-stage architecture​ — Optimal for 0.7–1.0 MPa applications; 20,000–40,000 hour airend life

  7. Power frequency (fixed-speed) operation​ — Lowest capital cost; ideal for steady-demand applications

  8. Direct drive​ — Eliminates belt losses (5–8% efficiency drop) and reduces maintenance points

  9. Tank capacity​ — 200L (compact), 250L (standard), 300–500L (multi-station buffer)

  10. Integrated dryer​ — Refrigerated achieving ≤ +3°C dew point; 1.2 m³/min capacity matches compressor output

  11. Filtration chain​ — Intake (3–5 μm) + coalescing (0.01 μm, ≤3 ppm oil) + particulate + optional activated carbon

  12. Motor protection​ — IP54, Class F insulation, thermal overload on all 3 phases

  13. Starter type​ — Star-Delta for 7.5KW to limit inrush current to 30% of DOL

  14. Discharge temperature​ — ≤Ambient +15°C; monitor for early warning of airend wear

  15. Oil capacity & service​ — 4L lubricant; 3,000-hour oil/filter/separator change interval (first at 500 hours)

  16. Airend service life​ — 20,000–40,000 hours expected with disciplined maintenance

  17. Footprint & weight​ — 890×650×830mm, 190–200 kg (standalone); 1430×710×1470mm, 380 kg (integrated 4-in-1)

  18. Ambient operating range​ — -5°C to +45°C; ensure adequate ventilation for heat rejection (7–10KW)

  19. Control system​ — PLC controller (e.g., MAM series) with pressure monitoring, fault diagnostics, and remote alarm

  20. Certifications​ — CE, ISO 1217, ISO 9001 compliance

  21. Warranty & support​ — Minimum 12-month warranty; documented 3,000-hour service schedule; global service network preferred

A single stage power frequency screw air compressor rated at 2980 r/min, 7.5KW, 78±2 dB(A), and 380V 50Hz represents the definitive value-driven solution for small-to-medium industrial compressed air applications. By combining the proven reliability of single-stage screw compression, the electrical simplicity of fixed-speed 2-pole motor operation at 2980 r/min, the global compatibility of 380V 50Hz three-phase power, and the straightforward maintenance profile of a direct-drive oil-lubricated airend, this configuration delivers 35–42 CFM of steady 8-bar air at the lowest capital cost per CFM in its class.

Whether you're outfitting an automotive 4S shop, a woodworking studio running orbital sanders and HVLP spray guns, a metal fabrication workshop using plasma cutting and pneumatic tools, a plastic injection molding facility, a textile jet loom operation, a small assembly line, or a 4S service center, the 7.5KW single-stage power frequency screw compressor offers a specification-perfect solution. The 20,000–40,000 hour airend service life , the 100% transmission efficiency of direct drive , the global 380V 50Hz compatibility, and the minimal maintenance requirements (oil change every 3,000 hours) make these units the clear choice for cost-conscious operators who prioritize reliability and value over premium features.

The initial investment in a quality 7.5KW single-stage power frequency compressor is recovered within 12–18 months through eliminated piston compressor downtime (rotary screw runs continuously without cylinder wear), reduced energy consumption vs. piston alternatives (verified 31% electricity bill reduction in real automotive workshop deployment ), prevented pneumatic tool failures from clean ≤3 ppm oil-content air , and the extended airend life that comes from disciplined 3,000-hour maintenance adherence. Across a decade of operation, the cumulative savings in equipment longevity, energy efficiency, and reduced downtime make the 7.5KW single-stage power frequency configuration not merely the best technical choice for its application class—but the only responsible one for any facility where reliable, steady, cost-effective compressed air directly impacts production continuity and profitability.

 

Tags:

Contact Us

unionaircompressor.com

Mobile:8618267307420

QQ:503155169

Mail:503155169@qq.com

Add:Hongxing Road, Economic and Technological Development Zone, Jiaxing City, Zhejiang Province,China

Order:Screw Air Compressor 2980r/min 7.5KW 78±2dB(A) 380V 50Hz

Related / RELATED PRODUCTS